Call 08047639232 82% Response Rate

Send Enquiry

our range

Termiticide

Pioneers in the industry, we offer bifenthrin 2.5% ec, chlorpyriphos 2% rtu, fipronil 2.92% w/w ec and imidacloprid 30.5% sc from India.

BIFENTHRIN 2.5% EC

BIFENTHRIN 2.5% EC
Get Best Quote
Rs 910  / LitrePrice on Request

Minimum Order Quantity: 100 Litre

FormulationBIFENTHRIN 2.5% EC
Product TypeTermiticide
Application TypeTermite Control
Composition2.5 %
BrandBithrin 25
Target PestsTermites
Packaging TypePlastic Bottle
Technical NameBifenthrin

 

 

Bithrin 25

Bifenthrin 2.5% EC

(Contact Insecticide)

 

Bifenthrin 2.5 % EC is a contact insecticide recommended for the control of termites in buildings and wood borers in wood.

Recommendations:

Bifenthrin 2.5% EC is contact insecticides recommended for control of: Termites in building or pre & post construction treatment Wood borers (powder post beetle) in plywood  veneer and wood

Direction of use:

Bifenthrin 2.5 % EC shall be applied at 0.5 %  a.i. concentration i.e 20.0 ml formulated product diluted in 1 litre of water for the control of termites in buildings during pre-construction. Treatment should be as per IS 6313(part-2 ) 2001  for pre-construction chemical treatment and IS 6313 (Part 3) : 2001 for past construction treatment of the existing building.

Treatment Of Masonry Foundations:

1. Bottom surface and sides of foundation pits up to a height of 30 cm Should be treated @ 5 ltr .Chemical emulsion per sq.mtr of surface area.

2.Back fill earth in immediate contact with the foundation structure should be treated @ 7.5 ltr per sq. mtr of the vertical surface of the substructure for each side.

3.Treatment of RCC Foundation: treatment should start at a depth of 50 cm below ground level @ 7.5 ltr per sq.mtr.

4. Treatment of top surface op plinth filling: the top surface of the consolidated earth within  plinth walls shall be treated with chemical emulsion at the rate of 5 ltr/m2 of the surface before the sand bed or sub-grade is laid.

5. Soil treatment along external perimeter of building: Earth along the external walls of the building should be rodded at intervals of 15cm and to a depth of 30cm exposing the foundation wall surface chemical solution should be poured along the wall @ 7.5 ltr per sq.mtr of vertical surface.

6. Treatment of soil under apron along external perimeter of building: Top surface of the earth over which the apron is to be laid shall be treated with chemical solution @ 5 ltr per sq.mtr of the vertical surface.

Post Construction: 

1. Soil Treatment along external perimeter of building: Earth along the external walls of the building should be rodded at intervals of 15cm and to a depth of 30cm exposing the foundation wall surface. chemical solution should be poured along the wall @ 7.5 ltr per sq mtr of vertical surface.

2. Treatment of soil under apron along external perimeter of building: top surface of the earth over which the apron is to be laid shall be treated with chemical solution @ 5 ltr per sq.mtr of the vertical surface.

3. Treatment of soil under floor: to prevent entry of termites from cracks, soil under floor should be treated. drill 12mm holes at the junction of floor and wall at 30 cm interval to reach the soil below. squirt the chemical solution @ 1 ltr per hole and seal.

4. Treatment of voids in masonry: the movement of termites through masonry walls may be restricted by drilling holes in masonry wall at about 45? angle preferably from both sides of the plinth wall at 30cm interval and squirt the chemical in holes till refusal and seal the holes.

5. Treatment of upper floors: in case of infestation in upper floors, treat ground floor of the existing building as described above.

Equipment:

Hand operated knapsack sprayer or foot sprayer is recommended.

Recommendation for control of wood borer(powder post beetle)in plywood , veneer and wood:

Plywood:

i)Apply 400ml formulation/m3 of wood as glue line poisoning.

ii)Mix 1ltr of formulation in 99ltr of water to make 0.025% solution and applied by dipping method.

Veneer: Mix 1 ltr of formulation 99 ltr  of water to make 0.025% solution and applied by dipping method.

 



Additional Information:

  • Production Capacity: 1000
  • Delivery Time: 3

View Complete details

Yes! I am Interested Request a call back

CHLORPYRIPHOS 2% RTU

CHLORPYRIPHOS 2% RTU
Get Best Quote
Rs 465  / LitrePrice on Request

Minimum Order Quantity: 100 Litre

ConcentrationCHLORPYRIPHOS 2% RTU
FormRTU
Packaging Size1 L
BrandWHITEOFF RTU
Target PestTermites
Technical NameChlorpyrifos
Physical StateLiquid
Brand Name :- WHITEOFF RTU

 

It is ready to use formulation containing  chlorpyriphos  a.i 2% w/w balance solvent it is recommended for protecting woods from the attack of termites and borers.

Recommendations:

Spray the wood surfaces  throughly ensuring complete coverage and absorption. Surfaces containing moisture need repeat application to achieve better control. Termiseal prevents and protects and treated wood from infestation of termites and borers.

Direction of Use:

Chlorpyriphos  2% w/w can be applied by using air compressed sprayers fitted with hollow come nozzle. Susceptible wood varieties can be treated  by dipping to ensure thorough  absorption.



Additional Information:

  • Production Capacity: 1000
  • Delivery Time: 3

View Complete details

Yes! I am Interested Request a call back

FIPRONIL 2.92% W/W EC

FIPRONIL 2.92% W/W EC
Get Best Quote
Rs 1,950  / LitrePrice on Request

Minimum Order Quantity: 100 Litre

Technical ContentFIPRONIL 2.92% W/W EC
Packaging Size1 litre
Crop UsageSugarcane, Rice, Chilli, Cotton
Formulation TypeEC
Target InsectThrips, Termite, Stem Borer, Aphid, Sucking Insects, Soil-Dwelling & Chewing Pests
Usage TypeFoliar Spray
Packaging TypeBottle
Grade StandardAgro Grade
Country Of OriginIndia
Brand Name :- Pexter
Recommendation

 

              Fipronil 2.92% w/w Emulsifiable Concentrate (EC) is recommended for the control of termites in buildings through pre & post construction treatments.
Direction Of Use

 

Fipronil 2.92% w/w EC (Agenda? 25 EC) shall be applied at 0.25% a.i. concentration i.e. 100 ml formulated product diluted in 1 litre of water for the control of termites in buildings during pre and post construction. Treatment should be as per IS 6313 (Part-2) : 2001 i.e. Pre-constructional chemical treatment measures and IS 6313 (Part-3) : 2001 i.e. treatment for existing building as follows. Pre-Construction: The chemical emulsion shall be applied uniformly at the prescribed rate in all the stages of treatment. Hand operated sprayer or watering can should be used for application of chemical emulsion. Treatment of Masonry Foundations: 1. Bottom surface and sides of foundation pits upto a height of 30 cm should be treated @ 5 ltr. chemical emulsion per sq. mtr of surface area. 2. Back fill earth in immediate contact with the foundation structure should be treated @ 7.5 ltr per sq. mtr. of the vertical surface, of the substructure for each side. 3. Treatment of RCC Foundations: Treatment should start at a depth of 50 cm below ground level @ 7.5 ltr. per sq. mtr. 4. Treatment of Top surface of plinth filling: The top surface of the consolidated earth within plinth walls shall be treated with chemical emulsion at the rate of 5 ltr/m2 of the surface before the sand bed or sub-grade is laid. 5. Soil treatment along external perimeter of building: Earth along the external walls of the building should be rodded at intervals of 15 cm and to a depth of 30 cm exposing the foundation wall surface. Chemical solution should be poured along the wall @ 7.5 ltr per sq. mtr of vertical surface. 6. Treatment of soil under apron along external perimeter of Building: Top surface of the earth over which the apron is to be laid shall be treated with chemical solution @ 5 ltr per sq. mtr. of the vertical surface. Post Construction: 1. Soil treatment along external perimeter of building: Earth along the external walls of the building should be rodded at intervals of 15 cm and to a depth of 30 cm exposing the foundation wall surface. Chemical solution should be poured along the wall @ 7.5 ltr per sq. mtr. of vertical surface. 2. Treatment of soil under apron along external perimeter of Building: Top surface of the earth over which the apron is to be laid shall be treated with chemical solution @ 5 Ltr per sq. mtr. of the vertical surface. 3. Treatment of soil under floor: To prevent entry of termites from cracks, soil under floor should be treated. Drill 12 mm holes at the junction of floor and wall at 30 cm interval to reach the soil below. Squirt the chemical solution @ 1 ltr per hole and seal. 4. Treatment of voids in masonry: The movement of termites through masonry walls may be restricted by drilling holes in masonry wall at about 45? angle preferably from both sides of the plinth wall at 30 cm interval and squirt the chemical in holes till refusal and seal the holes. 5. Treatment of Upper Floors: In case of infestation in upper floors, treat ground floor of the existing building as described above. Equipment: Hand operated knapsack sprayer or foot sprayer is recommended.

Symptoms Of Poisoning

 

Mainly consists of irritability, lethargy, muscle tremors and in extreme cases convulsions may occur. Fipronil is a reversible GABA receptor inhibitor and these symptoms are reversible after termination of exposure.

 

 

 



Additional Information:

  • Production Capacity: 1000
  • Delivery Time: 3

View Complete details

Yes! I am Interested Request a call back

IMIDACLOPRID 30.5% SC

IMIDACLOPRID 30.5% SC
Get Best Quote
Rs 3,340  / LitrePrice on Request

Minimum Order Quantity: 100 Litre

Technical ContentIMIDACLOPRID 30.5% SC
Packaging Size1 litre
Crop Usagesugarcane, mango, chillies, tomatoes, groundnut, grapes, Cotton, Paddy
Formulation TypeSC
Target Insectsucking insects
Usage TypeFoliar Spray
Packaging TypeBottle
Grade StandardAgro Grade
Country Of OriginIndia
Brand Name :- Pexter 

 

It is a systemic insecticide containing imidacloprid active ingredient, balance auxiliaries and insert material. It is used for control of termites in buildings.

Recommendation:It is used for control of termites in building  as follows: 

PRE- CONSTRUCTION :

The chemical emulsion shall be applied uniformly at at the prescribed rate in all the stages of treatment. Hand operated sprayer or watering can should be used for application  of chemical emulsion.

TREATMENT OF MASONRY FOUNDATIONS:

1. Bottom surface and sides of foundation  pits upto a height of 30 cm should be trated @ 5ltr.chemical  emulsion per sq. mtr. of surface area.2. Back fill earth in immediate contact with the foundation structure shoul be treated @7.5 ltr. per sq. mtr. of the vertical surface of the substructure for each side.3  Treatment of RCC Foundation: Treatment should start at a depth of 50 cm below ground level @7.5ltr. per sq.mtr.4. Treatment of  Top surface of plinth filling : The top surface of the consolidated earth within plinth wall shall be treated with chemical emulsion at the rate of 5ltr/ m2 of the surface before the sand bed or sub grade is laid. 5. Soil treatment along external  perimeter of building: Earth  along the external walls of the building should  be rodded at intervals of 15cm and to a depth of 30cm exposing  the Foundation  wall surface. Chemical solution  should be poured along the wall @ 7.5 ltr. per sq. mtr. of vertical surface. 6. Treatment of soil under apron along external perimeter of building:Top surgface of the Earth over which  the apron is to be laid shall be treated with chemical solution @ 5ltr per sq. mtr. of the vertical surface.

POST CONSTRUCTION:

1. Soil treatment  along external perimeter of building: Earth along the external walls of the building should be rodded at intervals of 15cm and a depth of 30cm exposing the foundation wall surface. Chemical solution shoud be poured along the wall @7.5 ltr.per sq. mtr. of vertical surface.2. Treatment of soil under apron along external perimeter of building : Top surface of the earth over which the apron is to be laid shall be treated  with chemical  solution @ 5ltr. per sq. mtr. of the vertical surface.3. Treatment of soil under floor: To prevent entry of termites from cracks,soil under floor should be treated. Drill 12mm holes at the junction of floor and wall at 30cm interval to reach the soil below squirt the chemical solution @ 1ltr. per hole and seal.4. Treatment of  voids in masonry : the movement of termites through masonry wall may be restricted by drilling holes in masonry wall at about 45 degree angle preferably from both sides of the plinth wall at 30cm interval and squirt the chemical in holes till  refusal and seal the holes.5. Treatment of upper floors : In case of infestation in upper floors, trat ground floor of the existing  building as described above 

                                         

 

 




Additional Information:

  • Production Capacity: 1000
  • Delivery Time: 3

View Complete details

Yes! I am Interested Request a call back

EXPLORE MORE CATEGORIES